Difference between revisions of "Datonis Edge 6.1 Release Notes"
From Datonis
(Added new feature list) (Tag: Visual edit) |
|||
(4 intermediate revisions by the same user not shown) | |||
Line 39: | Line 39: | ||
** The tunneling was causing security-related issues | ** The tunneling was causing security-related issues | ||
* Fixed: Edge stops working after getting Gateway Unauthorize Exception. (Needed to restart) | * Fixed: Edge stops working after getting Gateway Unauthorize Exception. (Needed to restart) | ||
+ | |||
+ | '''6.1.1211 - 26_Nov_2022 - Minor release''' | ||
+ | * Changed default scan and send interval to 5000 and 30000 milliseconds respectively. | ||
+ | * Added description to the scan and the send interval fields as "Scan interval should fully divide scan interval". | ||
+ | * Showing a warning and not letting apply the changes if the above condition (Scan Interval should fully divide the send interval) is not satisfied. | ||
+ | '''6.1.1222 - 14_Dec_2022 - Minor release''' | ||
+ | * Fixed : Sending the heartbeat on the configured time interval | ||
+ | * Fixed: UNKNOWN_ERROR was received whenever changes are made in the adapter configuration. | ||
+ | * Removed registerThing Datonis API call as it is deprecated. | ||
+ | |||
+ | '''6.1.1231 - 06_Jan_2023 - Minor release''' | ||
+ | * Added Openethernet HaaS Adapter to main Edge Build (There is no more Custom Openethernet Adapter build). | ||
+ | * Added long-term local SSL certificate for edge access on HTTPs (Secure ) channel. | ||
+ | * Added Automated Copy and Delete logs script to automatically detect the current folder and start copying logs of the last 7 days. | ||
+ | |||
+ | '''6.1.1250 - 02_Feb_2023 - Minor release''' | ||
+ | * Removed 'tag_' preffix while uploading configuration csv | ||
+ | * reInitializing Adapter on adapter stop condition. | ||
+ | * Milliseconds issue resolution | ||
+ | * Renamed OpenEthernet HaaS Adapter to Open Ethernet Adapter | ||
+ | * Upgraded OpcUA SDKs to version 0.5.2 |
Latest revision as of 13:13, 2 February 2023
Contents
Additions/Changes
[25_April_2022]
OPC DA XML Adapter
- OPC DA XML Adapter is used with the OPC DA-XML type of data server.
- This adapter uses SOAP-type requests from OPC DA-XML Server and reads the data from the same.
- Configuration: OPC DA (XML) Adapter -> Server URL, Username, password, and ID seperator.
Automatic Adapter Reset
- Automatic Adapter Reset is used if any particular adapter goes into the hung state for a certain time. The reason may be anything like server unavailable, or adapter disconnected eventually.
- It will continuously check if the adapter is in a hung state or not a by given time it will restart the adapter.
- Configuration: Any Adapter -> Settings -> Adapter Reset Interval (Seconds).
- Note: Minimum required time interval is 600 seconds (10 minutes). Setting it as -1 will disable this feature.
Monitor Tag Internal Send
- Monitor Tag Internal Send can help in sending the event data as it internally to Script Push Adapter.
- If this option is selected then the ‘tag_scanphase’ and ‘tag_scantime’ tags will be removed from the event data.
- In the case of the Monitor tag trigger, instead of sending the monitor tag only, it will send the whole event as it does for the datonis data sending.
- Configuration: Any Adapter -> Settings -> Publish Mode -> Monitor option.
- Note: All the options with Monitor suffix, work the same along with its prefixes.
Persistent Data Map across JS Tags and scripts
- Provided a variable as "persistent_global_val" to use across all the adapter JS Tags, Local Utility JS, and Global Utility JS Expression.
- "persistent_global_val" is a key-value type variable where data of any type(number, boolean, String) can be stored.
- the variable is available across all the adapters. eg. persistent_global_val.put("name":"abc"); this data will be available across all the adapters. Let it be OPC UA Adapter or Script Adapter.
- Note: This can not be used in script adapters connect, disconnect, read js expression and also can not be used in HTTP and MQTT adapters read js expression.
Improved Logs
- Improved the individual log file size to 25777216 and also increased the number of log rotations to 13.
BugFixes
- Fixed: Edge Upgrade wasn't working in the Docker Edge instance.
6.1.1146 - 29_June_2022 - Minor release
- Fixed: Milliseconds Events Bug
6.1.1195 - 27_Sep_2022 - Minor release
- Removed Edge Tunnel
- Removed the functionality to use Datonis Edge Remotely
- The tunneling was causing security-related issues
- Fixed: Edge stops working after getting Gateway Unauthorize Exception. (Needed to restart)
6.1.1211 - 26_Nov_2022 - Minor release
- Changed default scan and send interval to 5000 and 30000 milliseconds respectively.
- Added description to the scan and the send interval fields as "Scan interval should fully divide scan interval".
- Showing a warning and not letting apply the changes if the above condition (Scan Interval should fully divide the send interval) is not satisfied.
6.1.1222 - 14_Dec_2022 - Minor release
- Fixed : Sending the heartbeat on the configured time interval
- Fixed: UNKNOWN_ERROR was received whenever changes are made in the adapter configuration.
- Removed registerThing Datonis API call as it is deprecated.
6.1.1231 - 06_Jan_2023 - Minor release
- Added Openethernet HaaS Adapter to main Edge Build (There is no more Custom Openethernet Adapter build).
- Added long-term local SSL certificate for edge access on HTTPs (Secure ) channel.
- Added Automated Copy and Delete logs script to automatically detect the current folder and start copying logs of the last 7 days.
6.1.1250 - 02_Feb_2023 - Minor release
- Removed 'tag_' preffix while uploading configuration csv
- reInitializing Adapter on adapter stop condition.
- Milliseconds issue resolution
- Renamed OpenEthernet HaaS Adapter to Open Ethernet Adapter
- Upgraded OpcUA SDKs to version 0.5.2