Difference between revisions of "Datonis Edge 6.1 Release Notes"

From Datonis
Jump to: navigation, search
 
Line 53: Line 53:
 
* Added long-term local SSL certificate for edge access on HTTPs (Secure ) channel.
 
* Added long-term local SSL certificate for edge access on HTTPs (Secure ) channel.
 
* Added Automated Copy and Delete logs script to automatically detect the current folder and start copying logs of the last 7 days.
 
* Added Automated Copy and Delete logs script to automatically detect the current folder and start copying logs of the last 7 days.
 +
 +
'''6.1.1250 - 02_Feb_2023 - Minor release'''
 +
* Removed 'tag_' preffix while uploading configuration csv
 +
* reInitializing Adapter on adapter stop condition.
 +
* Milliseconds issue resolution
 +
* Renamed OpenEthernet HaaS Adapter to Open Ethernet Adapter
 +
* Upgraded OpcUA SDKs to version 0.5.2

Latest revision as of 13:13, 2 February 2023

Additions/Changes

[25_April_2022]

OPC DA XML Adapter

  • OPC DA XML Adapter is used with the OPC DA-XML type of data server.
  • This adapter uses SOAP-type requests from OPC DA-XML Server and reads the data from the same.
  • Configuration: OPC DA (XML) Adapter -> Server URL, Username, password, and ID seperator.

Automatic Adapter Reset

  • Automatic Adapter Reset is used if any particular adapter goes into the hung state for a certain time. The reason may be anything like server unavailable, or adapter disconnected eventually.
  • It will continuously check if the adapter is in a hung state or not a by given time it will restart the adapter.
  • Configuration: Any Adapter -> Settings -> Adapter Reset Interval (Seconds).
  • Note: Minimum required time interval is 600 seconds (10 minutes). Setting it as -1 will disable this feature.

Monitor Tag Internal Send

  • Monitor Tag Internal Send can help in sending the event data as it internally to Script Push Adapter.
  • If this option is selected then the ‘tag_scanphase’ and ‘tag_scantime’ tags will be removed from the event data.
  • In the case of the Monitor tag trigger, instead of sending the monitor tag only, it will send the whole event as it does for the datonis data sending.
  • Configuration: Any Adapter -> Settings -> Publish Mode -> Monitor option.
  • Note: All the options with Monitor suffix, work the same along with its prefixes.

Persistent Data Map across JS Tags and scripts

  • Provided a variable as "persistent_global_val" to use across all the adapter JS Tags, Local Utility JS, and Global Utility JS Expression.
  • "persistent_global_val" is a key-value type variable where data of any type(number, boolean, String) can be stored.
  • the variable is available across all the adapters. eg. persistent_global_val.put("name":"abc"); this data will be available across all the adapters. Let it be OPC UA Adapter or Script Adapter.
  • Note: This can not be used in script adapters connect, disconnect, read js expression and also can not be used in HTTP and MQTT adapters read js expression.

Improved Logs

  • Improved the individual log file size to 25777216 and also increased the number of log rotations to 13.

BugFixes

  • Fixed: Edge Upgrade wasn't working in the Docker Edge instance.
6.1.1146 - 29_June_2022 - Minor release
  • Fixed: Milliseconds Events Bug

6.1.1195 - 27_Sep_2022 - Minor release

  • Removed Edge Tunnel
    • Removed the functionality to use Datonis Edge Remotely
    • The tunneling was causing security-related issues
  • Fixed: Edge stops working after getting Gateway Unauthorize Exception. (Needed to restart)

6.1.1211 - 26_Nov_2022 - Minor release

  • Changed default scan and send interval to 5000 and 30000 milliseconds respectively.
  • Added description to the scan and the send interval fields as "Scan interval should fully divide scan interval".
  • Showing a warning and not letting apply the changes if the above condition (Scan Interval should fully divide the send interval) is not satisfied.

6.1.1222 - 14_Dec_2022 - Minor release

  • Fixed : Sending the heartbeat on the configured time interval
  • Fixed: UNKNOWN_ERROR was received whenever changes are made in the adapter configuration.
  • Removed registerThing Datonis API call as it is deprecated.

6.1.1231 - 06_Jan_2023 - Minor release

  • Added Openethernet HaaS Adapter to main Edge Build (There is no more Custom Openethernet Adapter build).
  • Added long-term local SSL certificate for edge access on HTTPs (Secure ) channel.
  • Added Automated Copy and Delete logs script to automatically detect the current folder and start copying logs of the last 7 days.

6.1.1250 - 02_Feb_2023 - Minor release

  • Removed 'tag_' preffix while uploading configuration csv
  • reInitializing Adapter on adapter stop condition.
  • Milliseconds issue resolution
  • Renamed OpenEthernet HaaS Adapter to Open Ethernet Adapter
  • Upgraded OpcUA SDKs to version 0.5.2