Additions/Changes

[25_April_2022]

OPC DA XML Adapter

  • OPC DA XML Adapter is used with the OPC DA-XML type of data server.
  • This adapter uses SOAP-type requests from OPC DA-XML Server and reads the data from the same.
  • Configuration: OPC DA (XML) Adapter -> Server URL, Username, password, and ID seperator.

Automatic Adapter Reset

  • Automatic Adapter Reset is used if any particular adapter goes into the hung state for a certain time. The reason may be anything like server unavailable, or adapter disconnected eventually.
  • It will continuously check if the adapter is in a hung state or not a by given time it will restart the adapter.
  • Configuration: Any Adapter -> Settings -> Adapter Reset Interval (Seconds).
  • Note: Minimum required time interval is 600 seconds (10 minutes). Setting it as -1 will disable this feature.

Monitor Tag Internal Send

  • Monitor Tag Internal Send can help in sending the event data as it internally to Script Push Adapter.
  • If this option is selected then the ‘tag_scanphase’ and ‘tag_scantime’ tags will be removed from the event data.
  • In the case of the Monitor tag trigger, instead of sending the monitor tag only, it will send the whole event as it does for the datonis data sending.
  • Configuration: Any Adapter -> Settings -> Publish Mode -> Monitor option.
  • Note: All the options with Monitor suffix, work the same along with its prefixes.

Persistent Data Map across JS Tags and scripts

  • Provided a variable as "persistent_global_val" to use across all the adapter JS Tags, Local Utility JS, and Global Utility JS Expression.
  • "persistent_global_val" is a key-value type variable where data of any type(number, boolean, String) can be stored.
  • the variable is available across all the adapters. eg. persistent_global_val.put("name":"abc"); this data will be available across all the adapters. Let it be OPC UA Adapter or Script Adapter.
  • Note: This can not be used in script adapters connect, disconnect, read js expression and also can not be used in HTTP and MQTT adapters read js expression.

Improved Logs

  • Improved the individual log file size to 25777216 and also increased the number of log rotations to 13.

BugFixes

  • Fixed: Edge Upgrade wasn't working in the Docker Edge instance.
6.1.1146 - 29_June_2022 - Minor release
  • Fixed: Milliseconds Events Bug

6.1.1195 - 27_Sep_2022 - Minor release

  • Removed Edge Tunnel
    • Removed the functionality to use Datonis Edge Remotely
    • The tunneling was causing security-related issues
  • Fixed: Edge stops working after getting Gateway Unauthorize Exception. (Needed to restart)