[[Datonis Edge Gateway|Edge Gateway Home]] > '''Edge Data Service Configuration'''
 
[[Datonis Edge Gateway|Edge Gateway Home]] > '''Edge Data Service Configuration'''
== Manual Upgrade ==
 
# Open old Gateway Web Console - http://localhost:8080/edge
 
# Download latest Settings Snapshot via navigating '''Settings -> Snapshots -> Download''' to have a clear text back up of all settings.
 
# Uninstall old Gateway build using '''bin/uninstall_edge_service.bat''' on Windows and '''bin/uninstall_edge_service.sh''' on Linux.
 
# Take '''backup''' of '''data folder''' of old gateway to restore in case upgrade fails.
 
# Extract new gateway build to a '''different folder''' other than old gateway installation folder.
 
# Copy old Gateway '''data folder''' at the bin folder level i.e. as child folder of '''datonis-edge-x.x.x folder'''.
 
# Install new Gateway build using '''bin/install_edge_service.bat''' on Windows and '''bin/install_edge_service.sh''' on Linux.
 
# Launch new Gateway Web Console - http://localhost:8080/edge
 
# Update SSL Configuration '''KeyStore Path''' to point to '''new Gateway installation folder''' via navigating '''Settings -> SSL Configuration -> Keystore path,''' change its value and click '''Apply.'''
 
# At this stage new Gateway must have been successfully upgraded, if you face any issue contact Altizon Support.
 
  
== Auto Upgrade ==
+
== Use HTTP Transport ==
# Extract new gateway build to a '''different folder''' other than old gateway installation folder.
+
 
# Copy the full path of the '''old Gateway installation - datonis-edge-x.x.x folder.'''
+
# True for HTTP type communication. False for MQTT type communication. (Default will be False.)
# Run the Upgrade Script using '''bin/upgrade_edge_service.bat''' on Windows and '''bin/upgrade_edge_service.sh''' on Linux.
+
 
# Paste the '''path of the old Gateway installation''' when prompted on the command line interface and press Enter.
+
== Connect Auto on Startup ==
# At this stage new Gateway must have been successfully upgraded.
+
 
# Launch new Gateway Web Console - http://localhost:8080/edge, if you face any issue contact Altizon Support.
+
# True for connecting automatically on edge restart or system startup. (Default will be True.)
 +
 
 +
== Retry Interval ==
 +
 
 +
# Data Connect retrial interval. (In Seconds. 0 to disable)
 +
 
 +
== Message Purge Age ==
 +
 
 +
# Age in seconds of completed messages (either published with QoS = 0 or confirmed with QoS > 0) after which they are deleted (minimum 5).
 +
 
 +
== Message Store Capacity ==
 +
 
 +
# Maximum number of messages persisted in the Data Store. The limit does not apply to messages with the priority less than 2. These priority levels are reserved to the framework which uses it for life-cycle messages - birth and death certificates - and replies to request/response flows.
 +
 
 +
== Message Store Size ==
 +
 
 +
# Maximum number of messages in the store batch size that if exceeded triggers the batch persist.
 +
 
 +
== Maximum Period to Prioritize Latest Messages ==
 +
 
 +
# Max period in seconds to determine latest messages. Messages older than the max period are considered stale and will be transmitted at a lower priority. To disable this feature mark this setting as 0 (Minimum period 300 seconds).
 +
 
 +
== Maximum Number of In-Flight Messages ==
 +
 
 +
# The maximum number of in-flight messages. This should not be less than 'transmit.bulk-size' value.
 +
 
 +
== Transmitting Messages Bulk Size ==
 +
 
 +
# Max transmit bulk size limit (minimum 1). The number of messages per request. (Suppose 5 then maximum 5 messages will be sent in a single request.)
 +
 
 +
== Messages Bulk Splitting by Thing ==
 +
 
 +
# Split bulk data message by thing to send transport requests per thing. (Thing 1s messages will be sent in 1st request then thing 2s and so on..)
 
__FORCETOC__
 
__FORCETOC__

Revision as of 11:49, 14 January 2022

Edge Gateway Home > Edge Data Service Configuration

Use HTTP Transport

  1. True for HTTP type communication. False for MQTT type communication. (Default will be False.)

Connect Auto on Startup

  1. True for connecting automatically on edge restart or system startup. (Default will be True.)

Retry Interval

  1. Data Connect retrial interval. (In Seconds. 0 to disable)

Message Purge Age

  1. Age in seconds of completed messages (either published with QoS = 0 or confirmed with QoS > 0) after which they are deleted (minimum 5).

Message Store Capacity

  1. Maximum number of messages persisted in the Data Store. The limit does not apply to messages with the priority less than 2. These priority levels are reserved to the framework which uses it for life-cycle messages - birth and death certificates - and replies to request/response flows.

Message Store Size

  1. Maximum number of messages in the store batch size that if exceeded triggers the batch persist.

Maximum Period to Prioritize Latest Messages

  1. Max period in seconds to determine latest messages. Messages older than the max period are considered stale and will be transmitted at a lower priority. To disable this feature mark this setting as 0 (Minimum period 300 seconds).

Maximum Number of In-Flight Messages

  1. The maximum number of in-flight messages. This should not be less than 'transmit.bulk-size' value.

Transmitting Messages Bulk Size

  1. Max transmit bulk size limit (minimum 1). The number of messages per request. (Suppose 5 then maximum 5 messages will be sent in a single request.)

Messages Bulk Splitting by Thing

  1. Split bulk data message by thing to send transport requests per thing. (Thing 1s messages will be sent in 1st request then thing 2s and so on..)