Difference between revisions of "Upgrading Datonis Edge Gateway"
From Datonis
(→Auto Upgrade) (Tag: Visual edit) |
(Edge up-gradation for docker installation.) (Tag: Visual edit) |
||
Line 20: | Line 20: | ||
# At this stage new Gateway must have been successfully upgraded. | # At this stage new Gateway must have been successfully upgraded. | ||
# Launch new Gateway Web Console - http://localhost:8080/edge, if you face any issue contact Altizon Support. | # Launch new Gateway Web Console - http://localhost:8080/edge, if you face any issue contact Altizon Support. | ||
+ | |||
+ | == Docker Installation Upgrade == | ||
+ | The below steps illustrate the migration of datonis-edge-6.0.1100 to datonis-edge-6.0.1102: | ||
+ | * Stop the old container | ||
+ | {| class="wikitable" | ||
+ | |sudo docker stop datonis-edge-6.0.1100 | ||
+ | |} | ||
+ | * Install new Datonis edge container | ||
+ | {| class="wikitable" | ||
+ | |docker run --name datonis-edge-6.0.1102 --mount type=volume,source=edge-vol,target=/opt/datonis-edge-data --publish 8080:8080 --publish 8443:8443 --detach --restart unless-stopped altizon/linux-edge:6.0.1102 | ||
+ | |} | ||
+ | |||
__FORCETOC__ | __FORCETOC__ |
Latest revision as of 19:26, 17 March 2022
Edge Gateway Home > Upgrading Datonis Edge Gateway
Manual Upgrade
- Open old Gateway Web Console - http://localhost:8080/edge
- Download latest Settings Snapshot via navigating Settings -> Snapshots -> Download to have a clear text back up of all settings.
- Uninstall old Gateway build using bin/uninstall_edge_service.bat on Windows and bin/uninstall_edge_service.sh on Linux.
- Take backup of data folder of old gateway to restore in case upgrade fails.
- Extract new gateway build to a different folder other than old gateway installation folder.
- Copy old Gateway data folder at the bin folder level i.e. as child folder of datonis-edge-x.x.x folder.
- Install new Gateway build using bin/install_edge_service.bat on Windows and bin/install_edge_service.sh on Linux.
- Launch new Gateway Web Console - http://localhost:8080/edge
- Update SSL Configuration KeyStore Path to point to new Gateway installation folder via navigating Settings -> SSL Configuration -> Keystore path, change its value and click Apply.
- At this stage new Gateway must have been successfully upgraded, if you face any issue contact Altizon Support.
Auto Upgrade
- Extract new gateway build to a different folder other than old gateway installation folder.
- Copy the full path of the old Gateway installation - datonis-edge-x.x.x folder.
- Run the Upgrade Script using bin/upgrade_edge_service.bat on Windows and bin/upgrade_edge_service.sh on Linux.
- Paste the path of the old Gateway installation when prompted on the command line interface and press Enter.
- At this stage new Gateway must have been successfully upgraded.
- Launch new Gateway Web Console - http://localhost:8080/edge, if you face any issue contact Altizon Support.
Docker Installation Upgrade
The below steps illustrate the migration of datonis-edge-6.0.1100 to datonis-edge-6.0.1102:
- Stop the old container
sudo docker stop datonis-edge-6.0.1100 |
- Install new Datonis edge container
docker run --name datonis-edge-6.0.1102 --mount type=volume,source=edge-vol,target=/opt/datonis-edge-data --publish 8080:8080 --publish 8443:8443 --detach --restart unless-stopped altizon/linux-edge:6.0.1102 |